TP&C Line Design Subcommittee 15.11
Updated
May
22, 2011
Chair:
Rich Collins - CAI Scope: Treatment of all matters of economical and technical design, theoretical and experimental performance, installation, and service operation of transmission and distribution conductors and overhead ground wires, their supporting structures, associated splicing and
hardware components, and counterpoise and structure grounding.
|
Steering Working Group 15.11.01 Chair: Dale A. Douglass Power Delivery Consultants, Inc
|
|
|
Scope: To assist and advise the Chairman of the TP&C Line Design Subcommittee on matters of administration, coordination and planning for the subcommittee and its working groups.
|
|
|
.
|
|
W.G. ON T&D OVERHEAD CONDUCTORS & ACCESSORIES 15.11.02/06 Chair: Craig Pon Kinectrics
Vice Chair: Neal Chapman - LS Power Development
|
|
|
Scope: Treatment of all matters pertaining to the mechanical, electrical, thermal and environmental aspects of overhead transmission and distribution conductors, shieldwires and accessories. As the following
relate to conductors, shieldwires and accessories;
- to encourage, and to provide a forum for, the exchange of information and experiences among utilities, suppliers, consultants and academic institutions;
- to create and maintain, IEEE standards, papers and other documents as appropriate;
- to provide a forum for introduction of new technologies;
- to provide a forum for individuals to network with others who have common interests;
- to provide liaison with other industry groups with similar interests;
- to keep abreast of new or emerging areas and issues and to take action, if required
Standards 664, 738, 1283, 1368
|
|
|
.
|
|
W.G. on Construction of Overhead Lines 15.11.03 Chair: Doug Proctor - Proctor Engineering, Inc.
|
|
|
Scope: Investigate, evaluate and report on methods, equipment and tools that have been found practical for assembly and erection of structures, installation of foundations, grounding, and stringing of overhead transmission line conductors and overhead ground wires. To coordinate, review and develop papers, guides, standards and related efforts directed toward more efficient, safer and higher quality construction of overhead transmission
lines.
Standards 524, 951, 1025, 1441, 977
|
|
|
.
|
|
W.G. on T&D Line Design Methods 15.11.04/05 Chair:
Jerry Reding - JLR Engineering, LLC
Vice Chair: Len Custer - BPA
|
|
|
Scope: The treatment of all matters related to the environmental loading (ice and wind) and structural performance of transmission line structures, conductor systems, and associated components. Overhead line design methods and permitting activities necessary to evaluate meeting simultaneous routing, economic, and environmental transmission line constraints.
|
|
|
Standards 691
|
|
|
|
W.G. on TP&C Changes to the NESC 15.11.07 Chair: Nelson G. Bingel, III - Osmose Wood Preserving, Inc.
|
|
|
Scope: Address issues related to the National Electrical Safety Code and submit change proposals on behalf of the working group. Monitor other significant change proposals and conduct educational sessions.
|
|
|
.
|
|
W.G. on T&D Overhead Line Structural Materials & Hardware 15.11.08/10 Chair: Keith E.
Lindsey Lindsay Manufacturing Co.
|
|
|
Scope: To promote, coordinate, review, develop, and execute technical papers, guides, standards, bibliographies, and related efforts concerning design, testing and installation of overhead line structures and line hardware for use on electric power transmission and distribution lines.
|
|
|
.Standards 751, 1217, 1218,
C135
|
|
|
|
W.G. on Management of Existing O.H. Transmission Lines 15.11.09 Chair: Andy Stewart - EDM International, Inc.
|
|
|
Scope: To provide a forum for information exchange and discussion of existing technologies and technology needs for inspection, assessment, management and utilization of overhead lines. Develop papers or guides to present methods for assessing and extending the life expectancy and optimizing the use of the components of existing overhead lines.
|
|
|
|
W.G. on CORONA &
FIELD EFFECTS 15.11.11 Chair: David Phillips - Space and Naval Warfare Systems Center - U.S. Navy
Vice-Chair: Glenn Davidson - Power Engineers
|
|
|
Scope: Analysis and calculation of corona on conductors, structures and hardware. Analysis and calculation of electric and magnetic fields on and near conductors, structures and hardware
Standards
|
|
|
|
W.G. on TRANSMISSION & DISTRIBUTION CORROSION Management (teg368)
15.11.12 Chair: Neal Murray Electric Power Research Institute Vice-Chair: Ken Brown Bonneville Power Secretary: Hank Kleinfelder Pole Maintenance Company
|
|
|
Scope: To provide an open forum for electric utilities, consultants, and industry suppliers to discuss grounding and corrosion issues in electrical power and transmission and distribution systems. The mission is to produce guides and standards for inspection, mitigation, and remediation of corrosion damage on T&D facilities.
|
|
|
|
W.G. on HVDC LINES 15.11.13 Chair: John Chan - EPRI Vice-Chair: Secretary:
|
|
|
Scope:
The treatment of all matters related to the
design of HVDC overhead lines including the selection of line components and
the design of electrodes and associated electrode lines. Design
requirements for upgrading AC lines to DC operation are also to be covered.
|
|
|
|
W.G. on INSULATOR PERFORMANCE AND
APPLICATIONS 15.11.14 Chair: Andrew Philips - EPRI & Allen Bernstorf -
Hubbell Power Systems Vice-Chair: Secretary:
|
|
|
Scope: To study
and evaluate new technologies and traditional approaches in the use of
dielectric materials for outdoor insulators in transmission, distribution
and substation installations.
|
|